FreeStyle Libre 3.

By Abbott

FDA ClearedContinuous Glucose Monitor

Abbott's FreeStyle Libre 3 — the world's most-used CGM sensor — delivers real-time glucose readings every minute with 14-day wear, iCGM accuracy (MARD 7.9%), and LibreView cloud integration for seamless RPM programs.

Specifications

Key specs.

01

Sensor Wear Time

Up to 14 days

02

Reading Frequency

Every 1 minute

03

Accuracy (MARD)

7.9%

04

FDA Classification

iCGM cleared

05

Warm-Up Time

60 minutes

06

Calibration

Factory calibrated — no fingersticks

07

Connectivity

Bluetooth Low Energy to smartphone app

08

Cloud Platform

LibreView (cloud-to-cloud API)

09

Water Resistance

Up to 1 meter for 30 minutes

10

Sensor Size

Smallest and thinnest iCGM sensor available

Features

Key features.

Real-time glucose readings every 1 minute — 1,440 readings per day

14-day sensor wear — longest of any iCGM sensor

Factory calibrated with no fingerstick calibration required

Real-time glucose alerts for highs, lows, and signal loss

No scanning required — continuous Bluetooth streaming

LibreView cloud platform for remote data sharing

Ambulatory Glucose Profile (AGP) reporting

Smallest and thinnest iCGM sensor available

Water resistant up to 1 meter for 30 minutes

Compatible with iOS and Android smartphones

Use Cases

Clinical applications.

01

Type 1 diabetes management

02

Type 2 diabetes on insulin therapy

03

Gestational diabetes monitoring

04

Medicare RPM program enrollment (CPT 99454 compliance)

05

Senior living diabetes monitoring

06

Endocrinology practice RPM programs

The World's Most-Used CGM Sensor

FreeStyle Libre 3 is Abbott's latest continuous glucose monitoring sensor and the most-used CGM platform globally with over 5 million users across 60+ countries. For RPM programs, it delivers a combination that no other CGM matches: readings every minute, 14-day sensor wear, and iCGM-level accuracy with a MARD of 7.9%.

Where traditional blood glucose meters provide 2-4 data points per day, FreeStyle Libre 3 generates 1,440 — revealing the complete glucose picture that spot-checks miss.

How FreeStyle Libre 3 Works with CCN Health

Data flows from the sensor to CCN Health's clinical platform through Abbott's LibreView cloud:

  1. Sensor measurement — The subcutaneous filament measures interstitial glucose every minute automatically
  2. Bluetooth relay — Readings transmit via Bluetooth Low Energy to the FreeStyle Libre app on the patient's smartphone
  3. LibreView cloud sync — The app syncs data to Abbott's LibreView cloud platform in real time
  4. CCN Health integration — CCN Health pulls glucose data from LibreView's cloud API, processes time-in-range metrics, generates clinical alerts, and posts summaries to the patient's EHR

This end-to-end automation means clinical staff see glucose trends, alerts, and AGP reports without requiring any manual data entry from the patient or provider.

Clinical Decision Support

FreeStyle Libre 3's minute-by-minute data unlocks clinical insights that 5-minute CGMs cannot provide at the same resolution:

  • Time-in-range analytics — Percentage of time glucose stays within target range (70-180 mg/dL), the gold-standard metric endorsed by the international diabetes technology community
  • Pattern recognition — Dawn phenomenon, post-meal spikes, overnight hypoglycemia, and exercise response patterns visible with higher granularity
  • Predictive alerting — Configurable thresholds for urgent low, low, and high glucose events. CCN Health escalates critical events to care teams automatically
  • AGP reports — Standardized 14-day ambulatory glucose profile reports for clinical review and documentation

FreeStyle Libre 3 vs FreeStyle Libre 2

Feature Libre 3 Libre 2
Reading frequency Every 1 minute Every 1 minute
Real-time alerts Yes (always on) Yes (Libre 2 Plus)
Scanning required No Optional (scan or real-time)
Sensor wear 14 days 14 days
MARD accuracy 7.9% 9.2%
Sensor size Smallest iCGM sensor Standard size
FDA classification iCGM iCGM
Warm-up 60 minutes 60 minutes

CMS Compliance for RPM Billing

FreeStyle Libre's continuous data transmission supports CPT 99454 compliance by automatically documenting device transmission days. Each day with at least one glucose reading counts toward the 16-day minimum required for monthly RPM billing. With readings every minute, the Libre 3 consistently generates qualifying data on every day the sensor is active — reducing the most common cause of RPM billing failures.

Ordering and Logistics

FreeStyle Libre 3 is available through standard medical supply distributors and direct from Abbott. CCN Health's platform tracks sensor inventory, monitors sensor expiration timelines, and automates patient outreach for sensor replacement to maintain continuous monitoring coverage.

Questions?

Want to learn more about the FreeStyle Libre 3 for your program?

Our team can answer your questions and show you how it works with your current workflow.

How CCN Health Helps

From setup to scale.

01

Discovery & Setup

We learn your workflows, EHR configuration, and patient population — then configure CCN’s platform to match.

02

Launch & Monitor

Devices ship directly to patients, data flows into your EHR automatically, and our clinical team monitors around the clock.

03

Scale & Optimize

Expand enrollment, add new programs, and let AI-driven insights continuously improve outcomes and reimbursement.

Ready to Get Started?

Deploy FreeStyle Libre 3 to your patients.

Book a short discovery call and we’ll map out a program tailored to your workflows, EHR, and patient population.

Contact Us

Drop Us a Message

Have a question about RPM, CCM, or how CCN Health can help your organization? Send us a message and our team will respond within 24 hours.

Response within 24 hours
HIPAA-compliant communications
No commitment required

Send Us a Message

By submitting this form, you agree to our privacy policy. We'll never share your information.