Two-Way Vital Sync PointClickCare Integration Explanation

Follow one reading from the resident's room onto the PointClickCare chart, then watch a nurse-charted vital flow the other way. Six steps, both directions.

Start the explanation
Step by step
1

A vital gets taken in Harold's room. This morning it is his blood pressure, on rounds.

It works the same from a cellular cuff, the CCN app, or a contactless sensor.

The facilityCCN HealthPointClickCare
The facility· where the reading happens
Room 214-B · the reading

Harold's reading

Blood pressure

132/78

captured just now

On rounds

a caregiver with the CCN app and a shared Bluetooth cuff

In the room

a cellular device, no wifi, no pairing

Overnight

a contactless sensor reads from the wall

How it works

What happens

A reading gets taken in the room: a cellular device, a caregiver with the CCN app and a shared Bluetooth device, or a contactless sensor overnight. It travels to CCN Health on its own, gets checked against the resident's thresholds, and is written onto the PointClickCare chart tagged with the correct device type. And it works the other way too: when a nurse charts a vital directly in PointClickCare, CCN ingests it within seconds, so both systems always show the same current, deduplicated set.

How it works

CCN is built on PointClickCare's Partner API (connect2.pointclickcare.com). Device readings webhook into CCN, are matched to the resident, deduplicated, and posted as observations (POST /api/public/preview1/orgs/{org}/observations) with the device type on the record. In the other direction CCN reads the facility's charted observations (GET .../observations) and reconciles them: a same-minute duplicate is recognized and skipped rather than double-charted, and an observation struck out in PointClickCare is removed from CCN automatically.

The benefit to your practice

One set of vitals, both directions, no transcription in either system. The nurse charts where she always charts, the devices chart themselves, and the monitoring team, the facility, and the record all agree. Double-charting and copy-paste errors simply stop existing.

What you get

  • Eight vital types: BP, heart rate, SpO₂, temperature, weight, glucose, sleeping HR, respiratory rate
  • Bidirectional: device readings write to the chart, nurse-charted vitals flow back within seconds
  • Duplicate readings reconciled on both sides, never charted twice
  • Struck-out observations in PointClickCare auto-remove from CCN