Infrared thermometers
Fast, contactless temperature monitoring with connected data transmission for RPM programs. Choose from cellular and Bluetooth options that fit your clinical workflow.
98.6°F · read in one second
The patient experience
Point, press, one second.
The patient or caregiver positions the device an inch or two from the center of the forehead, presses the measurement button, and receives a reading in one second. No skin contact, no disinfection between uses.
In real life
One second, then back to the day.
Each temperature reading transmits automatically to the CCN Health platform. Clinicians track trends across their entire patient panel, with configurable fever and hypothermia alerts that trigger before symptoms escalate.

How readings flow
From the forehead to your dashboard.
Configure per-patient alert thresholds based on age, condition, and immunocompromised status. Fever and hypothermia alerts trigger immediate clinical team notifications.
Take Temperature Reading
Patient points the infrared thermometer at the forehead or ear. A reading displays on the screen in about one second.
Automatic Transmission
The device transmits the temperature reading automatically via cellular or Bluetooth. No manual logging or smartphone apps needed.
Monitor Trends Remotely
Clinical staff track temperature trends over time on the CCN Health dashboard. Fever alerts flag abnormal readings for follow-up.
What your team sees.
Helen M. · Non-contact infrared
97-99.5°F
Normal
99.5-100.3°F
Low-Grade
≥100.4°F
Fever
Helen M.
98.6°F
Walter B.
100.8°F
Patricia R.
97.9°F
George L.
99.7°F
Betty S.
95.4°F
Cellular or Bluetooth. Zero Wi-Fi required.
Every reading reaches the platform without home Wi-Fi or a patient smartphone requirement. Choose the pathway that fits each patient.
Built-in cellular
Standalone cellular
The Tenovi cellular thermometer carries a built-in SIM: readings transmit automatically over the cellular network. No gateway, no phone, no Wi-Fi required.
Bluetooth Low Energy
Through the cellular gateway
Bluetooth thermometers pair with the Tenovi Gateway, which relays each reading over the cellular network. Pairing is established during initial device configuration.
Supported thermometers.
Cellular and Bluetooth infrared thermometers for every clinical workflow.

Tenovi Thermometer
Cellular infrared thermometer with built-in SIM. Readings transmit automatically over the cellular network. No gateway, no phone, no Wi-Fi required.

Jumper FTA10
Bluetooth-enabled infrared thermometer supporting ear, forehead, and ambient modes. Pairs with the Tenovi Gateway or smartphone app for data transmission.
Clinical-grade accuracy.
Clinical-grade accuracy in a lightweight, easy-to-use form factor. Non-contact infrared technology measures temperature without skin contact, making it comfortable and hygienic for patients of all ages.
Accuracy
±0.4°F (±0.2°C)
Speed
~1 second reading
Technology
Non-contact infrared
Modes
Forehead + surface
Connectivity
Bluetooth to Gateway
Fever Threshold
≥100.4°F (38°C)
Hypothermia
<96°F (sepsis indicator)
Power
AAA × 2
FDA-Cleared
FDA-cleared non-contact infrared sensors deliver ±0.4°F clinical-grade accuracy. Bluetooth connectivity with HIPAA-compliant encrypted data transmission to the CCN Health platform.
Non-Invasive Comfort
Infrared technology measures temperature without skin contact, making it comfortable and hygienic for patients of all ages. Ideal for elderly and cognitively impaired populations.
Multi-Mode Options
Ear, forehead, and ambient temperature modes give clinicians flexibility to choose the best measurement method for each patient and care setting.

On the platform
The answers, straight.
CCN Health supports non-contact infrared thermometers and oral digital thermometers with wireless connectivity. Readings transmit via cellular or Bluetooth to the CCN Health platform for clinical review.
Temperature monitoring is common in post-surgical monitoring, infection surveillance in senior living facilities, immunocompromised patient management, and chronic inflammatory condition tracking. It is often paired with other vital sign monitoring.
All devices are FDA-cleared with clinical-grade accuracy (±0.2°F / ±0.1°C for oral thermometers, ±0.4°F / ±0.2°C for infrared). Non-contact infrared models provide instant readings without touching the patient.
Yes. Temperature is a qualifying physiologic parameter for RPM billing under CPT 99454 when ordered by a physician for a documented medical condition. It must be captured by an FDA-cleared device that transmits data electronically.
Yes. Facility-wide temperature monitoring supports infection surveillance programs. Early detection of fever trends across a community can trigger infection control protocols before outbreaks spread.
One platform, eleven device categories.
Thermometer is one piece. Cellular scales, glucose meters, pulse oximeters, sleep sensors, and more all feed the same dashboard, the same alerts, and the same billing engine.